Heating Equipment Sales and Rentals
 |
Direct Fired
|
 |
 |
 |
| Model |
TPE-500 |
TPE-2000 |
TPE-4000
|
| Heating Capacity BTU/hr |
100,000 - 500,000 |
400,000 - 2,000,000 |
1,750,000 - 4,000,000 |
| CFM |
4,600 |
12,000 |
22,250 |
| Fuel Type |
LP/NG |
LP/NG |
LP/NG |
| Max. Fuel Useage/Hr. |
5.46 gal. or
5 therms |
21.84 gal. or
20 therms |
43.67 gal. or
40 therms |
| Electrical Requirements |
115v
7 amps |
230/460v
3 phase
14/7 amps |
230/460v
3 phase
40/20 amps |
| Motor/HP |
1/2 |
5 |
15 |
| Weight - lbs. |
135 |
1300 |
1500 |
| Dimensions HxLxW (In.) |
30x42x20 |
54x105x48 |
79x132x64 |
| Certifications |
CSA/AGA |
UL Components |
UL Components |
|
Indirect Fired
|
 |
 |
| Model |
IDF-500-S |
IDF-2000 |
| Heating Capacity BTU/hr |
500,000 |
2,000,000 |
| CFM |
4,100 |
11,000 |
| Fuel Type |
#1 Fuel Oil or Kerosene* |
#1 Fuel Oil or Kerosene* |
| Fuel Consump. Setting |
3.6 gph |
14.3 gph |
| Electrical Requirements |
230v, 1ph
13 amps |
230v, 1 ph
23 amps |
| Motor/HP |
2 |
7.5 |
| Weight - lbs. |
750 |
3,000 |
| Dimensions HxLxW (In.) |
48x97x50 |
84x128x62 |
|
Certification
|
CSA Components
|
CSA Components
|
| * |
No. 1 fuel oil or kerosene is recommended when the ambient temperature is less than 8 degrees F (-10 degrees C). Discharge temperature (@ 50 degrees F ambient). |
|
National Headquarters, 900C Tryens Road, Aston, PA 19014, Call 610-558-0837
|
|